Last reviewed: May 2026 — EgressUSA editorial team

Michigan Egress Window Requirements — IRC 2015

Michigan enforces IRC 2015 through the Michigan Residential Code. The four core egress dimensions are unchanged from IRC 2015 through 2024 — every EgressUSA kit meets all MRC requirements and ships free to all Michigan addresses.

IRC 2015 Section R310 — Required in MI

5.7 ft²

Minimum net clear opening area

R310.2.1

24 in

Minimum net clear height

R310.2.2

20 in

Minimum net clear width

R310.2.3

44 in

Max. sill height from finished floor

R310.2.4

Code enforced
IRC 2015 (MRC)
Scope
Statewide — all residential construction
Permit required

Ships Free to MI

EgressUSA Kits Meet All MI Requirements

Boman Kemp + Egress Pros. MRC (IRC 2015) verified. Ships in 1–3 days.

Code Questions?

Our team answers Michigan egress questions daily.

Michigan Egress Window Requirements — IRC 2015

Michigan Residential Code (MRC) · IRC 2015 currently enforced statewide

Michigan enforces the Michigan Residential Code (MRC), which is based on IRC 2015 with Michigan-specific amendments. Michigan has not yet adopted the 2018, 2021, or 2024 IRC editions — the current enforceable standard across Michigan is IRC 2015. If you are finishing a basement bedroom, preparing a home for sale, or bringing a rental unit into compliance anywhere in Michigan, your egress window must meet all four MRC Section R310 requirements.

The important thing for Michigan homeowners and contractors to understand is that the four core egress window dimensions under Section R310 have not changed between IRC 2015 and IRC 2024. A window that meets IRC 2015 requirements automatically meets the current standard — and will meet IRC 2021 and IRC 2024 if and when Michigan upgrades its code. Every EgressUSA kit is compliant with Michigan’s current MRC requirements.

Detail Value
Code enforced
IRC 2015 (MRC)
Governing code

Michigan Residential Code (MRC)

Adoption status

Michigan adopted IRC 2015 as the Michigan Residential Code — has not yet adopted 2018, 2021, or 2024 editions

Scope

Statewide — all residential construction

Permit required

✓ Yes — all Michigan municipalities

The 4 Required Egress Window Dimensions in Michigan

IRC 2015 Section R310.2 — Applies Statewide

Michigan enforces IRC 2015 which requires every basement sleeping room to have an emergency escape and rescue opening meeting all four of the following criteria simultaneously. A window that meets three out of four still fails inspection.

5.7

ft²

Minimum net clear opening area (820 sq inches)

24

inches

Minimum net clear height of the opening

20

inches

Minimum net clear width of the opening

44

inches

Maximum sill height above finished floor

Window Well Requirements (R310.4)

When the egress window opening is below grade — which applies to virtually every basement installation — IRC 2015 also requires a window well with: minimum 9 square feet floor area, minimum 36-inch width and projection from the foundation wall, and a permanently affixed ladder if the well depth exceeds 44 inches/

Michigan-Specific Amendments & Important Notes

State Amendments · Local Exceptions · Additional Requirements

While Michigan enforces IRC 2015, there are important state-specific considerations every homeowner and contractor must be aware of before starting an egress window project.

Key Cities in Michigan — Local Code Notes

City-Level Enforcement · Local Amendments · Building Department Contacts

Even within Michigan’s statewide MRC, individual municipalities handle permits and enforcement through their own building departments. Here are the key markets and what you need to know for each.

Detroit / Wayne County

MRC (IRC 2015)
Detroit enforces the Michigan Residential Code. Detroit Building Safety Engineering and Environmental Dept issues permits. High volume of basement egress projects — permits typically processed within 2–3 weeks.

Grand Rapids

MRC (IRC 2015)
Grand Rapids enforces MRC statewide standard. City of Grand Rapids Building Department handles permits. One of Michigan’s most active residential construction markets.

Lansing

MRC (IRC 2015)
State capital enforces MRC. City of Lansing Building Safety Office issues permits. Contact (517) 483-4355 for permit inquiries.

Ann Arbor

MRC (IRC 2015)
Ann Arbor enforces MRC. City of Ann Arbor Building and Housing Services. High demand for basement egress — strong enforcement of bedroom egress requirements.

Flint

MRC (IRC 2015)
Flint enforces the Michigan Residential Code. Genesee County Building Department serves surrounding areas. Contact your local municipality for permit applications.

Traverse City / Northern MI

MRC (IRC 2015)
Northern Michigan municipalities all enforce the MRC statewide standard. Permit enforcement may be less frequent in rural townships — but the legal requirement is the same statewide.

Permits & Inspection in Michigan

Building Permit · Local Inspection · What to Submit

A building permit is required in all Michigan municipalities for egress window installation. Egress window installation involves cutting through a structural foundation wall — this is universally classified as a structural alteration and triggers the permit requirement. Working without a permit creates risk of forced removal, insurance voidance, and complications at sale.

A building permit is required in all Michigan municipalities for egress window installation. Egress window installation involves cutting through a structural foundation wall — a structural alteration that triggers permit requirements under the Michigan Residential Code. Working without a permit creates risk of forced removal, insurance voidance, and complications at sale.

What to Submit for Your Permit Application

Most Michigan municipalities require the following for an egress window permit application:

Ships Free to Michigan

Every EgressUSA Kit Is MI-Ready

Boman Kemp + Egress Pros. Pre-verified to MRC (IRC 2015). Pass your Michigan local building inspection on the first visit — guaranteed.

Michigan Egress Window Requirements — FAQ

Common questions about Michigan egress window code, permits, and compliance

Michigan enforces the Michigan Residential Code (MRC), which is based on IRC 2015 with Michigan-specific amendments. Michigan has not yet adopted the 2018, 2021, or 2024 IRC editions. All four MRC Section R310 requirements apply statewide: 5.7 sq ft minimum opening area, 24-inch minimum clear height, 20-inch minimum clear width, and 44-inch maximum sill height above finished floor.
For egress window dimensions, no. The four core requirements under Section R310 — 5.7 sq ft, 24 inches, 20 inches, 44 inches — have not changed between IRC 2015 and IRC 2024. A window and kit that meets Michigan’s MRC automatically meets the current IRC 2024 standard. Every EgressUSA kit sold today will pass Michigan building inspection under the current MRC.
Yes. Egress window installation in Michigan requires a building permit in all municipalities because it involves cutting through a structural foundation wall — a structural alteration that triggers permit requirements under the MRC. Building permits in Michigan are issued at the local level through city, township, or village building departments. Contact your local building official before starting work.
Yes. The Michigan Residential Code requires every basement sleeping room to have at least one emergency escape and rescue opening that meets all four MRC R310 requirements. This applies to new construction and any renovation that creates or establishes a new sleeping room in a basement. Michigan home inspectors consistently flag missing egress windows in basement bedrooms during real estate transactions.
Yes. EgressUSA ships free to all Michigan addresses including the Detroit metro area, Grand Rapids, Lansing, Ann Arbor, and all Upper Peninsula addresses. Kits are verified to meet Michigan Residential Code requirements and are designed to pass Michigan local building inspection on the first visit. Orders ship within 1–3 business days.
Michigan has not announced a specific timeline for adopting IRC 2018, 2021, or 2024. The Michigan Bureau of Construction Codes manages the adoption process. Based on current MRC 2015 enforcement, contractors and homeowners should design and build to the current MRC standard. Because the core R310 egress dimensions are the same across all IRC editions, any compliant kit installed today will remain compliant after any future Michigan code update.

Neighboring States

Ohio

IRC 2017

Indiana

IRC 2020

Wisconsin

IRC 2021

Illinois

Local Only