Last reviewed: May 2026 — EgressUSA editorial team

Massachusetts Egress Window Requirements — 780 CMR (IRC 2021)

Massachusetts enforces IRC 2021 through the 10th Edition of 780 CMR, effective as the sole code after June 30, 2025. Every EgressUSA Egress Pros tilt-turn kit meets the standard 5.7 sq ft requirement and ships free to all Massachusetts addresses.

780 CMR Section R310 — Required in MA

5.7 ft²

Minimum net clear opening area

R310.2.1

24 in

Minimum net clear height

R310.2.2

20 in

Minimum net clear width

R310.2.3

44 in

Max. sill height from finished floor

R310.2.4

Code enforced
IRC 2021 (780 CMR)
Scope
Statewide — all residential construction
Permit required

Ships Free to MA

EgressUSA Kits Meet All MA Requirements

Boman Kemp + Egress Pros. 780 CMR (IRC 2021) verified. Ships in 1–3 days.

Code Questions?

Our team answers Massachusetts egress questions daily.

Massachusetts Egress Window Requirements — 780 CMR (IRC 2021)

Massachusetts State Building Code, 10th Edition (780 CMR) — based on IRC 2021 · 10th Edition effective October 11, 2024 — sole enforced code after June 30, 2025 (780 CMR)

Pennsylvania enforces the Pennsylvania Uniform Construction C

Massachusetts enforces the Massachusetts State Building Code, 10th Edition (780 CMR), based on IRC 2021 with significant Massachusetts-specific amendments. The 10th Edition became the sole enforced code after June 30, 2025 — any permit pulled for an egress window installation in Massachusetts today must comply with the 10th Edition. If you are finishing a basement bedroom, preparing a home for sale, or bringing a rental unit into compliance anywhere in Massachusetts — your egress window must meet the Section R310 requirements of 780 CMR.

Massachusetts enforces the Massachusetts State Building Code, 10th Edition (780 CMR), based on IRC 2021 with significant Massachusetts-specific amendments. The 10th Edition became the sole enforced code after June 30, 2025 — any permit pulled for an egress window installation in Massachusetts today must comply with the 10th Edition. If you are finishing a basement bedroom, preparing a home for sale, or bringing a rental unit into compliance anywhere in Massachusetts — your egress window must meet the Section R310 requirements of 780 CMR.

Massachusetts has one significant amendment to the standard IRC egress window requirements that every homeowner must understand: the double-hung window exception. Under 780 CMR, double-hung windows in one- and two-family dwellings may qualify as egress windows with a minimum net clear opening of 3.3 square feet — lower than the standard IRC 5.7 sq ft requirement. However, this exception applies only to double-hung windows. All other window styles — including casement, slider, and tilt-turn windows like those sold by EgressUSA — must meet the standard 5.7 sq ft, 24-inch, 20-inch, and 44-inch requirements. The Egress Pros tilt-turn windows EgressUSA carries meet the standard 5.7 sq ft requirement and are fully compliant with 780 CMR.

ode (PA UCC), which is based on IRC 2021 with Pennsylvania-specific amendments. The PA UCC updated to IRC 2021 effective January 1, 2026 — making Pennsylvania current with the 2021 I-Codes. The PA UCC is administered by the Pennsylvania Department of Labor and Industry, though enforcement is handled at the local level through municipal building code officials. If you are finishing a basement bedroom, preparing a home for sale, or bringing a rental unit into compliance anywhere in Pennsylvania — your egress window must meet all four PA UCC Section R310 requirements.

An important distinction for Pennsylvania homeowners: the City of Philadelphia enforces its own Philadelphia Building Code, which is based on the IBC rather than the IRC. If your project is within Philadelphia, verify requirements with the Philadelphia Department of Licenses and Inspections (L&I) at phila.gov/li rather than relying solely on the PA UCC. Additionally, some Pennsylvania municipalities have opted out of the state-administered PA UCC program. In opt-out municipalities, the Pennsylvania Department of Labor and Industry handles commercial code enforcement, while property owners must hire a certified third-party inspection agency to enforce residential requirements. Verify with your local municipality whether they are state-administered or opt-out before applying for a permit.

Detail Value
Code enforced
IRC 2021 (780 CMR 10th Ed)
Governing code

Massachusetts State Building Code, 10th Edition (780 CMR) — based on IRC 2021

Adoption status

10th Edition effective October 11, 2024 — sole enforced code after June 30, 2025 (780 CMR)

Scope

Statewide — all residential construction — enforced locally by municipal building officials

Permit required

✓ Yes — all municipalities

The 4 Required Egress Window Dimensions in Massachusetts

780 CMR Section R310.2 — Applies Statewide in MA

Massachusetts (780 CMR) requires every basement sleeping room to have an emergency escape and rescue opening meeting all four of the following criteria simultaneously. A window that meets three out of four still fails inspection.

5.7

ft²

Minimum net clear opening area (820 sq inches)

24

inches

Minimum net clear height of the opening

20

inches

Minimum net clear width of the opening

44

inches

Maximum sill height above finished floor

Window Well Requirements (R310.4)

When the egress window opening is below grade — which applies to virtually every basement installation — 780 CMR also requires a window well with: minimum 9 square feet floor area, minimum 36-inch width and projection from the foundation wall, and a permanently affixed ladder if the well depth exceeds 44 inches.

Massachusetts-Specific Amendments & Important Notes

State Amendments · Local Exceptions · Additional Requirements

While Massachusetts enforces 780 CMR (IRC 2021), there are important state-specific considerations every homeowner and contractor must be aware of before starting an egress window project.

Key Cities in Massachusetts — Local Code Notes

City-Level Enforcement · Local Amendments · Building Department Contacts

All Massachusetts municipalities enforce 780 CMR 10th Edition for egress requirements. The key variation is the energy code tier — Base, Stretch, or Specialized Stretch. Here are the key Massachusetts markets and what you need to know for each.

Boston

IRC 2021 (780 CMR 10th Ed + Specialized Stretch Code)
Boston enforces 780 CMR 10th Edition and has adopted the Specialized Stretch Code energy tier — the strictest energy requirements. City of Boston Inspectional Services Department (ISD) issues permits. Contact (617) 635-5300.

Worcester

IRC 2021 (780 CMR 10th Ed + Stretch Code)
Worcester enforces 780 CMR 10th Edition and has adopted the Stretch Code. Worcester Inspectional Services Division handles permits. Contact (508) 799-1180.

Springfield

IRC 2021 (780 CMR 10th Ed)
Springfield enforces 780 CMR 10th Edition. City of Springfield Building Department handles permits. Verify current energy code tier with the building department.

Cambridge / Brookline

IRC 2021 (780 CMR 10th Ed + Specialized Stretch Code)
Cambridge and Brookline have both adopted the Specialized Stretch Code — the strictest energy tier. Verify U-factor and SHGC requirements with your local building department before purchasing windows.

Lowell / Lawrence

IRC 2021 (780 CMR 10th Ed)
Lowell and Lawrence enforce 780 CMR 10th Edition. Contact your local building official for current energy code tier and permit requirements in these communities.

Suburban Boston / Metrowest

IRC 2021 (780 CMR 10th Ed — Stretch Code common)
Most suburban Boston communities (Newton, Framingham, Natick, Wellesley, etc.) have adopted the Stretch Code. Verify with your specific municipality. All enforce 780 CMR 10th Edition for egress requirements.

Permits & Inspection in Massachusetts

Building Permit · Local Inspection · What to Submit
 

A building permit is required in all Massachusetts municipalities for egress window installation. Egress window installation involves cutting through a structural foundation wall — this is universally classified as a structural alteration and triggers the permit requirement. Working without a permit creates risk of forced removal, insurance voidance, and complications at sale.

A building permit is required in all Massachusetts municipalities for egress window installation. Contact your local code enforcement officer before work begins.

What to Submit for Your Permit Application

Most Massachusetts municipalities require the following for an egress window permit application:

Ships Free to Massachusetts

Every EgressUSA Kit Is MA-Ready

Boman Kemp + Egress Pros. Pre-verified to 780 CMR (IRC 2021). Pass your Massachusetts local building inspection on the first visit — guaranteed.

Massachusetts Egress Window Requirements — FAQ

Common questions about Massachusetts egress window code, permits, and compliance

Massachusetts enforces the Massachusetts State Building Code, 10th Edition (780 CMR), based on IRC 2021 with Massachusetts-specific amendments. The 10th Edition is the sole enforced code for permits pulled after June 30, 2025. The standard egress window requirements under 780 CMR Section R310 are: 5.7 sq ft minimum opening area, 24-inch minimum clear height, 20-inch minimum clear width, and 44-inch maximum sill height above finished floor.
Yes — for double-hung windows only. Under 780 CMR (Massachusetts 10th Edition), double-hung windows in one- and two-family dwellings may qualify as egress windows with a minimum net clear opening of 3.3 square feet rather than the standard 5.7 sq ft. However, this exception applies ONLY to double-hung windows. All other window styles — including tilt-turn, casement, and slider windows — must meet the standard 5.7 sq ft IRC requirement. EgressUSA Egress Pros tilt-turn windows meet the standard 5.7 sq ft requirement and are fully compliant with 780 CMR.
The Massachusetts State Building Code is published as 780 CMR (Code of Massachusetts Regulations) and is administered by the Board of Building Regulations and Standards (BBRS). The current 10th Edition is based on IRC 2021 with significant Massachusetts-specific amendments. References to 780 CMR and the MA State Building Code refer to the same document.
Yes. Egress window installation in Massachusetts requires a building permit in all municipalities because it involves cutting through a structural foundation wall — a structural alteration under 780 CMR. Permits are issued by your local municipal building official — the building commissioner or inspector of buildings. Contact your local building department before work begins. Permit fees typically range from $100–$400 depending on municipality.
Yes. The Massachusetts State Building Code (780 CMR) requires every basement sleeping room to have at least one emergency escape and rescue opening meeting the applicable Section R310 requirements. This applies to new construction and any renovation that creates a new sleeping room in a basement. Massachusetts home inspectors consistently flag missing egress windows in basement bedrooms during real estate transactions.
Yes. EgressUSA ships free to all Massachusetts addresses including Boston, Worcester, Springfield, the MetroWest suburbs, Cape Cod, and all western MA communities. Kits feature Egress Pros tilt-turn windows which meet the standard 5.7 sq ft requirement under 780 CMR. Orders ship within 1–3 business days and arrive in 3–7 business days.

Neighboring States

New York

IRC 2024

Connecticut

IRC 2021

Rhode Island

IRC 2018

New Hampshire

IRC 2015