Last reviewed: May 2026 — EgressUSA editorial team

Maryland Egress Window Requirements — MBPS (IRC 2021)

Maryland enforces IRC 2021 through the Maryland Building Performance Standards (MBPS), with local jurisdictions permitted to add amendments. Every EgressUSA kit meets the MBPS IRC 2021 baseline and ships free to all Maryland addresses.

MBPS Section R310 — Required in MD

5.7 ft²

Minimum net clear opening area

R310.2.1

24 in

Minimum net clear height

R310.2.2

20 in

Minimum net clear width

R310.2.3

44 in

Max. sill height from finished floor

R310.2.4

Code enforced
IRC 2021 (MBPS)
Scope
Statewide — all residential construction
Permit required

Ships Free to MD

EgressUSA Kits Meet All MD Requirements

Boman Kemp + Egress Pros. MBPS (IRC 2021) verified. Ships in 1–3 days.

Code Questions?

Our team answers Maryland egress questions daily.

Maryland Egress Window Requirements — MBPS (IRC 2021)

Maryland Building Performance Standards (MBPS) — based on IRC 2021 · State adopted IRC 2021 via MBPS effective May 29, 2023 — local jurisdictions required to implement by May 29, 2024

Maryland enforces the Maryland Building Performance Standards (MBPS), which requires all local jurisdictions to use IRC 2021 as the minimum residential building code standard. Maryland’s Division of Labor and Industry adopted the 2021 I-Codes effective May 29, 2023, with local jurisdictions required to implement by May 29, 2024. If you are finishing a basement bedroom, preparing a home for sale, or bringing a rental unit into compliance anywhere in Maryland — your egress window must meet all four MBPS Section R310 requirements.

Maryland is a home rule state — local jurisdictions can add amendments to the MBPS baseline but cannot go below IRC 2021. This means egress window requirements may be stricter in some counties than others. Major jurisdictions like Montgomery County, Prince George’s County, Baltimore City, and Anne Arundel County each have their own building code ordinances layered on top of the state MBPS. Always verify with your specific county or city building department whether local amendments affect egress window requirements in your jurisdiction.

Detail Value
Code enforced
IRC 2021 (MBPS)
Governing code

Maryland Building Performance Standards (MBPS) — based on IRC 2021

Adoption status

State adopted IRC 2021 via MBPS effective May 29, 2023 — local jurisdictions required to implement by May 29, 2024

Scope

Statewide minimum baseline (MBPS) — local jurisdictions may add amendments; enforced by local building departments

Permit required

✓ Yes — all jurisdictions

The 4 Required Egress Window Dimensions in Maryland

MBPS Section R310.2 — Statewide Minimum in MD

Maryland (MBPS) requires every basement sleeping room to have an emergency escape and rescue opening meeting all four of the following criteria simultaneously. A window that meets three out of four still fails inspection.

5.7

ft²

Minimum net clear opening area (820 sq inches)

24

inches

Minimum net clear height of the opening

20

inches

Minimum net clear width of the opening

44

inches

Maximum sill height above finished floor

Window Well Requirements (R310.4)

When the egress window opening is below grade — which applies to virtually every basement installation — The MBPS also requires a window well with: minimum 9 square feet floor area, minimum 36-inch width and projection from the foundation wall, and a permanently affixed ladder if the well depth exceeds 44 inches.

Maryland-Specific Amendments & Important Notes\

State Amendments · Local Exceptions · Additional Requirements

While Maryland enforces the MBPS (IRC 2021), there are important state-specific considerations every homeowner and contractor must be aware of before starting an egress window project.

Key Cities in Maryland — Local Code Notes

City-Level Enforcement · Local Amendments · Building Department Contacts
 

Maryland’s MBPS sets an IRC 2021 minimum for all jurisdictions, but major counties have their own additional amendments. Here are Maryland’s key markets and the specific contacts you need.

Baltimore City

MBPS (IRC 2021) + Baltimore amendments
Baltimore City is an independent city with its own building code ordinances on top of MBPS. Baltimore City DHCD Office of Permits and Development Services handles permits. Contact (410) 396-3360.

Montgomery County

MBPS (IRC 2021) + Montgomery County amendments
Montgomery County has its own building code ordinances layered on MBPS. Montgomery County Department of Permitting Services handles permits. Contact (240) 777-0311. One of Maryland’s most active residential markets.

Prince George's County

MBPS (IRC 2021) + PG County amendments
Prince George’s County has its own building code amendments. PG County Department of Permitting, Inspections, and Enforcement (DPIE) handles permits. Contact (301) 636-2050.

Anne Arundel County / Annapolis

MBPS (IRC 2021) + AA County amendments
Anne Arundel County has its own amendments. Anne Arundel County Office of Inspections and Permits handles permits. City of Annapolis has a separate building office. Contact (410) 222-7700.

Frederick County

MBPS (IRC 2021)
Frederick County enforces the MBPS statewide standard. Frederick County Division of Permitting and Development Review handles permits. Contact (301) 600-1080.

Baltimore County

MBPS (IRC 2021) + Baltimore County amendments
Baltimore County (separate from Baltimore City) has its own building code amendments. Baltimore County Office of Permits, Approvals and Inspections handles permits. Contact (410) 887-3610.

Permits & Inspection in Maryland

Building Permit · Local Inspection · What to Submit

A building permit is required in all Maryland jurisdictions for egress window installation. Egress window installation involves cutting through a structural foundation wall — this is universally classified as a structural alteration and triggers the permit requirement. Working without a permit creates risk of forced removal, insurance voidance, and complications at sale.

A building permit is required in all Maryland jurisdictions for egress window installation. Contact your local code enforcement officer before work begins.

What to Submit for Your Permit Application

Most Maryland jurisdictions require the following for an egress window permit application:

Ships Free to Maryland

Every EgressUSA Kit Is MD-Ready

Boman Kemp + Egress Pros. Pre-verified to MBPS (IRC 2021). Pass your Maryland local building inspection on the first visit — guaranteed.

Maryland Egress Window Requirements — FAQ

Common questions about Pennsylvania egress window code, permits, and compliance

Maryland enforces the Maryland Building Performance Standards (MBPS), which requires all local jurisdictions to use IRC 2021 as the minimum residential building code. The state adopted IRC 2021 effective May 29, 2023, with local jurisdictions required to implement by May 29, 2024. All four MBPS Section R310 requirements apply as a minimum statewide: 5.7 sq ft minimum opening area, 24-inch minimum clear height, 20-inch minimum clear width, and 44-inch maximum sill height above finished floor.
 
Yes. Maryland is a home rule state — local jurisdictions can add amendments on top of the MBPS IRC 2021 baseline, but cannot go below it. Major counties like Montgomery County, Prince George’s County, Baltimore City, Baltimore County, and Anne Arundel County each have their own building code ordinances. Always verify with your specific county or city building department whether local amendments affect egress requirements in your jurisdiction.
Yes. Egress window installation in Maryland requires a building permit in all jurisdictions because it involves cutting through a structural foundation wall — a structural alteration under the MBPS. Permits are issued by local county or city building departments. Contact your specific county or city building department before starting work. Maryland has 23 counties and Baltimore City, each with its own building department.
Yes. The Maryland Building Performance Standards require every basement sleeping room to have at least one emergency escape and rescue opening meeting all four MBPS R310 requirements. This applies to new construction and any renovation that creates a new sleeping room in a basement. Maryland home inspectors consistently flag missing egress windows in basement bedrooms during real estate transactions, particularly in the active Northern Maryland and DC suburbs markets.
Yes. EgressUSA ships free to all Maryland addresses including the Baltimore metro area, all DC suburbs (Montgomery County, Prince George’s County), the Eastern Shore, Western Maryland, and the Annapolis area. Kits are pre-verified to meet Maryland MBPS (IRC 2021) requirements and designed to pass Maryland local building inspection on the first visit. Orders ship within 1–3 business days.
The Maryland Building Performance Standards (MBPS) is Maryland’s law requiring all local jurisdictions to use the same edition of the same I-codes — currently IRC 2021. The MBPS is administered by the Maryland Department of Labor’s Building Codes Administration. It sets the minimum floor that all Maryland jurisdictions must meet for residential construction. Local jurisdictions may add stricter amendments on top of the MBPS but cannot weaken it below the IRC 2021 standard.

Neighboring States

Pennsylvania

IRC 2021

Virginia

IRC 2021

West Virginia

IRC 2018

Delaware

IRC 2018